DT205B, DT225B, DT250B, DT275B, DT300B Manual Extract
General
This calibration allows improved precision of forward speed depending on: – the different tyre sizes available – radar (if fitted)
Procedure
1. Mark out a 100 m (328 ft) (depending on the unit of measurement selected) on a firm surface.
2. Start up the tractor, and then press and hold the display selector switch (A) for 15 seconds.
NOTE: The daily hourmeter resets to 0 after 5 seconds.
3. “CAL” should appear on the screen
4. Drive the tractor forwards at normal working speed.
NOTE: The tractor must always be moving before starting out on the measured course; otherwise calibration will be incorrect.
5. Press the display selector switch when crossing the starting line of the 100 m (328 ft) course.
6. “run” should appear on the screen.
7. Press the display selector switch when crossing the finish line of the course.
8. Press the display selector switch; the constant forward speed (theoretical) measured during calibration is displayed.
9. Press the display selector switch again; the actual constant forward speed (radar) measured during calibration is displayed on tractors fitted with radar.
10. Press the display selector switch a final time to return the instrument panel to normal operating mode.